/content/sps/gb/en/search-results.html

Industrial Fixed

RAEGuard 2 PID

RAEGuard 2 PID

Overview

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs)

Product Overview:

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.

The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

Features & Benefits:

  • Faster response time - Thanks to the sample flow-through design
  • Reduce maintenance cost - Easy to remove sensor module in hazardous locations without using of tools
  • No false alarms - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution

Quick Specs:

  • Digital Smart Sensor Technology
  • Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm
  • Operates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output
  • Graphic display and LED light status indicator for fault and alarm conditions

Fire and Gas Consultancy Services

Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Features & Benefits

  • Features
    • - Easy to remove sensor module in hazardous locations without using of tools
    • - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution
    • - Thanks to the sample flow-through design
    • Faster response time
    • No false alarms
    • Reduce maintenance cost

Features & Benefits

  • Features
    • - Easy to remove sensor module in hazardous locations without using of tools
    • - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution
    • - Thanks to the sample flow-through design
    • Faster response time
    • No false alarms
    • Reduce maintenance cost
  • Features : - Easy to remove sensor module in hazardous locations without using of tools|- Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution|- Thanks to the sample flow-through design|Faster response time|No false alarms|Reduce maintenance cost
Data Sheet
Name
Description
File Size
Date
Size
RAEGuard 2 PID - Data Sheet - Dutch
application/pdf 570.4 KB
6/13/2023
570.4 KB
RAEGuard 2 PID Data Sheet
application/pdf 406.17 KB
5/5/2021
406.17 KB
Manuals and Guides
Name
Description
File Size
Date
Size
RAEGuard 2 PID User Guide Rev-R ENG
application/pdf 3.76 MB
7/7/2022
3.76 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
5/5/2021
788.83 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
5/5/2021
930.69 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
11/1/2022
1.45 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
5/5/2021
884.37 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
5/5/2021
787.55 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
8/3/2022
820.7 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
5/5/2021
944.51 KB
Certificate
Name
Description
File Size
Date
Size
EU & UK Declaration of Conformity RAEGuard 2
application/pdf 557.92 KB
7/25/2023
557.92 KB
DigiPID EU Declaration of Conformity
application/pdf 213.06 KB
9/14/2022
213.06 KB
RAEGuard 2 PID Intrinsic Safety Report
application/pdf 50.9 KB
5/5/2021
50.9 KB
RAEGuard 2 PID Atex Certificate of Conformity
application/pdf 206.4 KB
5/5/2021
206.4 KB
RAEGuard 2 PID ATEX EC-Type Examiniation Certificate
application/pdf 964.3 KB
5/5/2021
964.3 KB
RAEGuard 2 PID DigiPID ATEX CE EU Declaration of Conformity
application/pdf 396.42 KB
5/5/2021
396.42 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
5/5/2021
1.3 MB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
5/5/2021
1.3 MB
Application Note
Name
Description
File Size
Date
Size
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
5/5/2021
655.59 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
5/5/2021
826.34 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
5/5/2021
1.1 MB
Name
Description
File Size
Date
Size
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
5/5/2021
788.83 KB
EU & UK Declaration of Conformity RAEGuard 2
557.92 KB
7/25/2023
557.92 KB
RAEGuard 2 PID - Data Sheet - Dutch
570.4 KB
6/13/2023
570.4 KB
DigiPID EU Declaration of Conformity
213.06 KB
9/14/2022
213.06 KB
RAEGuard 2 PID User Guide Rev-R ENG
3.76 MB
7/7/2022
3.76 MB
RAEGuard 2 PID Intrinsic Safety Report
50.9 KB
5/5/2021
50.9 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
5/5/2021
930.69 KB
A Guideline for Pid Instrument Response
1.45 MB
11/1/2022
1.45 MB
RAEGuard 2 PID Atex Certificate of Conformity
206.4 KB
5/5/2021
206.4 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
5/5/2021
655.59 KB
RAEGuard 2 PID ATEX EC-Type Examiniation Certificate
964.3 KB
5/5/2021
964.3 KB
RAEGuard 2 PID Data Sheet
406.17 KB
5/5/2021
406.17 KB
RAEGuard 2 PID DigiPID ATEX CE EU Declaration of Conformity
396.42 KB
5/5/2021
396.42 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
5/5/2021
826.34 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
5/5/2021
884.37 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
5/5/2021
787.55 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
8/3/2022
820.7 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
5/5/2021
944.51 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
5/5/2021
1.1 MB
DigiPID ATEX EC-Type Examination Certificate
1.3 MB
5/5/2021
1.3 MB
DigiPID ATEX EC-Type Examination Certificate
1.3 MB
5/5/2021
1.3 MB
Name
Description
File Size
Date
Size
RAEGuard 2 PID - Data Sheet - Dutch
570.4 KB
6/13/2023
RAEGuard 2 PID Data Sheet
406.17 KB
5/5/2021
RAEGuard 2 PID User Guide Rev-R ENG
3.76 MB
7/7/2022
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
5/5/2021
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
5/5/2021
A Guideline for Pid Instrument Response
1.45 MB
11/1/2022
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
5/5/2021
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
5/5/2021
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
8/3/2022
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
5/5/2021
EU & UK Declaration of Conformity RAEGuard 2
557.92 KB
7/25/2023
DigiPID EU Declaration of Conformity
213.06 KB
9/14/2022
RAEGuard 2 PID Intrinsic Safety Report
50.9 KB
5/5/2021
RAEGuard 2 PID Atex Certificate of Conformity
206.4 KB
5/5/2021
RAEGuard 2 PID ATEX EC-Type Examiniation Certificate
964.3 KB
5/5/2021
RAEGuard 2 PID DigiPID ATEX CE EU Declaration of Conformity
396.42 KB
5/5/2021
DigiPID ATEX EC-Type Examination Certificate
1.3 MB
5/5/2021
DigiPID ATEX EC-Type Examination Certificate
1.3 MB
5/5/2021
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
5/5/2021
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
5/5/2021
Application Note 000: RAE Systems PID Overview
1.1 MB
5/5/2021
Product Number
Image
SKU
Description
alt
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
alt
033-3035-000
alt
050-0000-005
DigiPID lamp, 10.6 ev, 1/2
alt
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
alt
430-B082-0H0
O-Ring,40x35x2.5mm, Silicon Rubber
alt
430-B083-0H0
O-Ring,8.5x4.5x2mm, Silicon Rubber
alt
490-0011-005
DigiPID external water trap filter (Pack of 5)
alt
490-0163-000
FILTER HOUSING GLASS AND STEEL
alt
490-0164-010
FILTER REPLACEMENTS PACK OF 10
alt
490-3039-000
PLUG, 3/4" NPT, Aluminium, ATEX & CSA Certified
Image
SKU
Description
alt
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
alt
033-3035-000
alt
050-0000-005
DigiPID lamp, 10.6 ev, 1/2
alt
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
alt
430-B082-0H0
O-Ring,40x35x2.5mm, Silicon Rubber
alt
430-B083-0H0
O-Ring,8.5x4.5x2mm, Silicon Rubber
alt
490-0011-005
DigiPID external water trap filter (Pack of 5)
alt
490-0163-000
FILTER HOUSING GLASS AND STEEL
alt
490-0164-010
FILTER REPLACEMENTS PACK OF 10
alt
490-3039-000
PLUG, 3/4" NPT, Aluminium, ATEX & CSA Certified