Features & Benefits
  • Detection as precise as 0.00046%
  • Five alarm levels and two sensitivity modes
  • One device protections up to 8,000 sq. feet
Quick Specs
  • External supply voltage: 18-30 VDC
  • Power reset: 1 sec.
  • Average operating current: 500 mA @ 24 VDC
Need Assistance?
USA
Call: 1-800-538-0363
Enter your name and phone number and a Honeywell representative will contact you shortly.
SSL Lock SSL Secure
Don't worry, we won't share your phone and email address. (privacy policy)

Product Overview

FAAST (Fire Alarm Aspiration Sensing Technology) provides extremely sensitive and accurate Very Early Warning detection and alarm, which gives facility managers precious time to take appropriate action to maintain business continuity before disaster strikes. FAAST is so precise that it can discern nuisance particulates such as dust, which reduces false alarm incidents that lead to costly downtime and unwarranted activation of connected suppression systems.

As an aspirating detector, FAAST draws air samples into its sensor through a pipe network, which allows the detector to provide accurate detection even in challenging environments such as fluctuating temperatures. Its smoke detection performance is built around its unique Dual Vision sensing technology. The sensor utilizes an extremely sensitive blue LED to provide Very Early Detection, up to 60 minutes before combustion. The sensor also uses an infrared laser to identify nuisances like dust that can cause false alarms, downtime and unwarranted activation of connected suppression systems. The detector interprets signals from both sources to provide the earliest and most accurate warning of the widest range of fires available.

For communications, FAAST provides an onboard Ethernet port for easy connection to a computer, a network, and the Internet, enabling facility managers to actively monitor and protect their environments from any Internet browser, smart phone, or mobile device. The detector can also e-mail status notifications to multiple addresses.

FAAST enables a fully customized detection strategy. The detector includes five programmable alarm levels, the most of any aspiration detector, and 10 pre-alert particulate levels, so thresholds can be set to meet specific site requirements. In addition, an Acclimate mode can automatically adjust FAAST’s sensitivity within specified parameters. For example, if usage for a protected area varies, the detector will adjust itself to provide the appropriate sensitivity to suit current environmental conditions. Sensitivity levels can also be programmed based on a schedule. This precision enables facility managers to mount an appropriate response.

Additional Features and Benefits:

  • Dual source (blue LED and infra-red laser) optical smoke detection with advanced algorithms detect a wide range of fires while maintaining enhanced immunity to nuisance particulates
  • Detection as precise as 0.00046 %/ft obscuration
  • Five alarm levels and two sensitivity modes
  • Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement
  • One device protects up to 8,000 sq. ft.
  • Advanced detection algorithms reject common nuisance conditions
  • PipeIQ™ software provides intuitive control over system layout, configuration, and monitoring
  • Five alarm levels can be programmed for latching or non-latching relays
  • Onboard Ethernet interface enables remote monitoring and e-mail status updates to computer or mobile devices
  • Fault indictors exhibit a broad spectrum of events
  • Unique air flow pendulum graph verifies pipe network functionality
  • Particulate graph displays subtle environmental changes for early problem indications
FAAST by Honeywell Analytics

Frequently Asked Questions

Have a question about the product features or warranty? Find the answers here.
We do not sell our products directly on our website but we would be happy to assist you with your gas detection needs.  On each product page you will see a red button on the right-hand side titled “HOW TO BUY”.  If you click on this button a form will appear which will go directly to one of our sales representatives once completed and submitted.  

You can also call one of our sales representatives directly.  Click here to go to the Contact Us page.  

There are two areas where you can access technical documents.  First, you can visit our Technical Library in the Support section of the website.  Here you will be able to access our entire catalog of documents and videos for all products – current and legacy products.  

You can also access the technical documents for each product on that product’s respective page within the website.    


Yes we do.  Check out our HA University training section to see what programs are available and sign up for any that you are interested in.  These courses are very informative and led by our expert engineers.  If you have any questions about training opportunities for yourself or your staff and would like to talk to a Honeywell representative, click here.

Check out the Product Inquiry page in the Contact Us section.  Here you’ll find sales contacts for each of our product lines and they can help you with any questions you may have from technical specifications to ordering information. 

Check out the Service & Repairs page in the Contact Us section.  Here you’ll find the contact information for our service centers in your region. 

There are several ways you can search for products on our website:

  • Click on the Products link in the main navigation to search by product lines.
  • Find products for a specific Industry or Application by clicking on the links in the main navigation bar at the top of the page.
  • Use our Gas Finder if you’re looking for a product that can detect a specific type of gas.
  • If you still can’t find the product you’re looking for, type the name of the product in the search bar at the top of the page.

Because we do not sell our products directly we cannot quote a specific price on our website.  Contact a sales representative through either the “HOW TO BUY” button on the product page or by calling them and they will be able to obtain pricing from local distributors in your area. 

Similar Products

Check out some of these similar products.

Looking For More Information?

Check out these documents. If you can't find what you're looking for here, check out our Technical Resource library.
Document
Assess Risk, Plan Accordingly Fact Sheet English US
Assess Risk, Plan Accordingly Fact Sheet English US
Language: English US
Document
Texas-Sized Retrofit is Big on Simplicity_Case Study English US
Texas-Sized Retrofit is Big on Simplicity_Case Study English US
Language: English US
Document
FAAST™ FAQ's English US
FAAST™ FAQ's English US
Language: English US
Document
Codes Address Aspirating Smoke Detection English US
Codes Address Aspirating Smoke Detection English US
Language: English US
Document
Study Reveals Significantly HigherSmoke Detection Accuracy for FAAST™ English US
Study Reveals Significantly HigherSmoke Detection Accuracy for FAAST™ English US
Language: English US
Document
Aspiration Detection: Positioned to Be More Flexible English US
Aspiration Detection: Positioned to Be More Flexible English US
Language: English US
Document
Safety Design to Preserve Artifacts and Critical Functions English US
Safety Design to Preserve Artifacts and Critical Functions English US
Language: English US
Document
Aspiration Detection: When Early Isn’t Soon Enough English US
Aspiration Detection: When Early Isn’t Soon Enough English US
Language: English US